Research Use Only • Premium Laboratory Standards

Free express shipping on orders $250+

Bench Sale · Early Black Friday Sale25%OffEvery research compoundEnds 30 November 2026Bacteriostatic water excluded · Discount codes don't apply to sale items
Certificates of Analysis

Independent test reports, published as issued.

A certificate of analysis is only worth as much as the laboratory that produced it and the reader's ability to check it. This page explains what our certificates are, how to read one, and exactly which products have been through independent testing so far.

4Compounds tested
11Reports published
98.590%Lowest purity recorded
100%Verifiable online

Two kinds of documentation, clearly labelled

A certificate of analysis issued by the manufacturer at the time of production records purity, identity and test method at the point of manufacture. We have always been upfront that these supplier issued documents are manufacturer documents rather than tests we commissioned ourselves, and that remains true. Where a certificate is available to publish, it appears on these pages, and if a product has no certificate shown here, one is not currently available.

What has changed is that a growing share of the catalogue now also carries an independent laboratory test report. These are produced by Janoshik Analytical, a laboratory that specialises in peptide analysis, on vials taken from the same production batches we sell. Each report is reproduced on these pages exactly as it was issued, and each one carries a unique verification key that any visitor can enter at janoshik.com/verify to confirm the report is genuine and unaltered. We do not summarise the results in our own words and ask you to trust the summary; the primary document is right here.

In plain English

A supplier certificate is the factory saying "this is what we made." An independent report is a separate laboratory saying "this is what we found when we tested it." Both have value, but only the second one can be checked by you without taking anyone's word for it. We publish the second kind wherever we have it, and we say clearly where we do not.

How to read a test report

Every Janoshik report follows the same layout, so once you can read one you can read them all. The top block identifies the job: a task number, the date testing was ordered, the date the sample physically arrived at the laboratory, the sample name, the manufacturer code and the batch reference where one was assigned. The middle block states which test was requested, and the results table below it gives the measured values. The bottom carries the analysis date, the analyst's signature and the verification key.

Content and purity

For a purity report the results table shows two numbers. The first is the quantity of the named peptide actually present in the vial, in milligrams, measured by high performance liquid chromatography (HPLC). The second is purity, expressed as a percentage: the proportion of everything the instrument detected that was the target peptide rather than a related impurity, truncated sequence or synthesis by product. A 10 mg retatrutide vial returning 11.34 mg at 99.076% purity means the vial slightly overfills its label claim and that roughly 99 parts in 100 of the peptide material is retatrutide.

Some reports are labelled as a blind test. This means the laboratory was asked to identify which of several candidate peptides was in the vial rather than being told in advance, which is a stronger check of identity than a straight confirmation.

Endotoxin

Bacterial endotoxin is a component of the outer membrane of certain bacteria that can remain in a preparation even after it is sterile. It is reported in endotoxin units per vial (EU/vial), measured by the limulus amoebocyte lysate (LAL) assay. Because every LAL method has a validated range, the report states that range: earlier reports used a 10 to 1,000 EU/vial method, so a result of "less than 10" is the correct reading and the bracketed figure is only an estimate below the validated floor. Later reports used a more sensitive method that reads accurately up to 10 EU/vial and returns an exact figure. Lower is better, and a figure near the top of a method's range is worth reading alongside that range rather than in isolation.

In plain English

Milligrams tells you how much is in the vial. Purity tells you how clean it is. Endotoxin tells you how free it is from bacterial residue. The verification key at the bottom lets you check that we have not touched any of those numbers.

Those are the fields these particular reports carry. For the wider question of what every field on a peptide certificate proves and what it cannot prove, including identity by mass spectrometry, net peptide content, counterion and the traceability fields whose absence matters most, see our guide to reading a certificate of analysis, which also puts the published reports through the same checklist.

Certificates of analysis by product

Independent test reports are published below for the products that have them. Products in the not yet available list have no certificate of analysis available at present. Independent testing is being rolled out across the catalogue by volume, price and demand, and a product moves into the tested group when its report is published.

Independently tested

Retatrutide

10 mg, 20 mg and 30 mg · Batches Blue 20260922, Purple 20260923 · Tested November 2026
6 reports
30 mg vial, batch Blue 20260922, analysed 2 November 2026
32.41 mg retatrutideContent
99.641%Purity
20 mg vial, batch Purple 20260923, analysed 2 November 2026
21.64 mg retatrutideContent
99.694%Purity
30 mg vial, analysed 8 July 2026
33.68 mg retatrutideContent
99.689%Purity
3.113 EU/vialEndotoxin
10 mg vial, analysed 8 July 2026
11.34 mg retatrutideContent
99.076%Purity
2.667 EU/vialEndotoxin

View reports

Tesamorelin

10 mg · Batch FSD0716 · Tested June 2026
2 reports
10.05 mgContent
98.590%Purity
below 10 EU/vial (1.222 EU/vial estimate)Endotoxin

View reports

GHK-Cu

100 mg · Batch 2026.08.10 · Tested August 2026
2 reports
96.94 mg GHK-Cu (81.13 mg GHK, 15.81 mg copper)Content
99.341%Purity
9.919 EU/vialEndotoxin

View reports

Certificate of analysis not yet available

A work in progress, deliberately

Independent testing is not yet in place for every product, and we would rather say that plainly than imply otherwise. Each report costs several hundred dollars per vial, and testing several vials from a batch is what makes a result meaningful, so the programme is being rolled out in order of sales volume, price point and how widely the compound is used across our customer base. The four compounds above were selected first on that basis. Products not yet independently tested move into the tested group as their reports come back.

If a compound you rely on is not listed and you would like it prioritised, contact us at support@globalbioanalytical.com.au. Demand from researchers is one of the inputs we use to decide what is tested next.

Supplier issued certificates

Where a manufacturer's certificate is published on these pages, it records the product name and molecular formula, HPLC purity percentage, the test method used, a batch or lot reference, the test date and the physical description of the material. Some fields on these documents are redacted before we publish them, and we want to be clear about which ones and why.

Visible on every certificate

  • Product name and molecular formula
  • Purity percentage (HPLC)
  • Test method used
  • Batch or lot reference
  • Test date
  • Physical description and appearance

Withheld

  • Manufacturing facility name
  • Manufacturer address and contact details
  • Internal supply chain identifiers

Supply chain confidentiality is standard practice across the research biochemical industry at every scale. Facility details are withheld to protect upstream commercial relationships, not to obscure quality data; the purity and identity information researchers actually rely on is left fully intact. The same principle applies to the independent reports above, where the only detail ever withheld is the name of the party that ordered the test.

Where the programme stands

  • Ongoing
    Certificate publishing

    Certificates of analysis are published on these pages as they become available. If a product has no certificate shown here, one is not currently available.

  • Complete
    First round of independent testing

    Retatrutide, tesamorelin, GHK-Cu and MOTS-c tested through Janoshik Analytical, with purity and endotoxin reports published above.

  • In progress
    Second round selection

    Remaining products ranked by volume and researcher demand for the next round of purity and endotoxin testing. Endotoxin testing for MOTS-c is included in this round.

  • Complete
    Certificate links on product pages

    Each independently tested product links directly from its product page to its certificate of analysis page, so the report is one tap from the vial.

  • Ongoing
    Batch level retesting

    As volume allows, new stock batches are retested so that the report on this page continues to describe the vial that ships.

Analytical results relate to the sample tested; batch to batch variation is possible and is the reason batch references are stated wherever assigned. Test reports describe the analytical characteristics of research materials only. Page last reviewed 12 November 2026. Reports verified at janoshik.com/verify using the keys shown.