Laboratory reference

Reading a certificate of analysis: what each field actually proves, and what it does not.

A certificate of analysis is the only evidence most laboratories will ever have about what is in a vial. It is also a document with no fixed format, no mandatory content and, for compounds with no pharmacopoeial monograph, no external body deciding what belongs on it. This article goes through the fields one at a time: what each measurement answers, what it cannot answer, and which absences should stop a batch from being used.

Global Bioanalytical Laboratories · Published 4 September 2026 · Last reviewed 10 September 2026 · 12 minute read

This page is reviewed when analytical guidance, Australian regulatory positions or our own certificate format change.

Laboratory bench showing the analytical sequence behind a certificate of analysis: sample vials, an autosampler, an HPLC stack, a mass spectrometer, chromatogram and spectrum panels, and a printed certificate on a clipboard
Important

Read this first

This article is about reading an analytical document. It describes compounds handled in vitro, it contains no administration guidance, and research peptides are not approved therapeutic goods. In 2026 the Therapeutic Goods Administration made unapproved peptide products a compliance priority and published what that means for anyone importing, compounding, promoting or supplying them.9, 10 We also supply research peptides, so we have a commercial interest in this subject. The way we deal with that is to describe the fields a certificate should carry regardless of who issued it, and to tie every claim below to a published source rather than to our own practice.

What a certificate is, and is not

A certificate of analysis is a summary of the tests run on one specific batch of material, issued by whoever ran them. For an approved medicine the tests are not optional: a generic peptide sold to the European Pharmacopoeia standard has its analyses specified by that pharmacopoeia, and the designation in the product name is what signals conformance.1 For a research compound with no monograph, nobody outside the issuing organisation decides what appears on the page. The certificate proves what it reports, under the methods it names, for the batch it names. It does not certify anything else, and it is not a regulatory approval of any kind.

That has a practical consequence worth stating before any of the individual fields. A certificate can be entirely accurate and still be close to useless, if what it reports is thin. A number without a method, a result without a batch, or a document that could describe any batch the supplier has ever sold is not evidence about the vial in your hand.

Identity: is it the right molecule

This is the first question and the one most often left unanswered. Identity is established by comparing measured values against the values expected for the intended structure, and the primary tool for a peptide is mass spectrometry, which gives the molecular weight of the material in the vial.1 Electrospray ionisation produces a series of multiply charged ions rather than one peak at the molecular weight, and those are deconvoluted into a single neutral mass. A certificate that shows the deconvoluted result, and ideally the spectrum behind it, is telling you something. A certificate that reports a purity percentage and never confirms identity has told you how pure something is without telling you what it is.

Bachem lists several other tools that speak to identity, including running the material beside a reference sample on analytical HPLC, where a genuine match elutes as a single peak rather than two, and amino acid composition, in which the peptide is hydrolysed by strong acid and the released amino acids are separated and quantified.1 That last method is worth understanding precisely, because it is often oversold. Amino acid analysis returns the composition of the molecule. It does not return the sequence.1

The same limitation applies, in a different form, to the intact mass. Two molecules built from the same residues in a different order weigh the same, so a matching mass is consistent with the intended sequence rather than proof of it. Confirming order requires fragmentation by tandem mass spectrometry or sequential chemical degradation. For most laboratory purposes an intact mass match plus a clean chromatogram is a reasonable standard. It is worth knowing where that standard stops.

Two panel schematic: a reverse phase HPLC chromatogram with a main peak, a shoulder impurity and two resolved impurities, and a deconvoluted mass spectrum showing the observed mass beside a deletion sequence and a sodium adduct
The two questions a certificate answers. Panel B is identity, the subject of this section: the deconvoluted mass compared against the theoretical mass, with a deletion sequence and an adduct sitting beside it. Panel A is purity, which the next section covers, including the shoulder impurity that gets counted inside the main peak. Schematic, not data from any batch.
In plain English

Two different questions get muddled constantly. Mass spectrometry asks what the thing is. Chromatography asks how much of what is in the vial is that thing. A certificate that answers only the second question has skipped the first, and a sample can be beautifully pure while being the wrong compound. Also worth knowing: matching the weight is strong evidence, not absolute proof, because the same building blocks in a different order weigh exactly the same.

Purity: how much of it is the right molecule

Purity for peptides is standardly assessed by analytical reverse phase HPLC with ultraviolet detection at 210 to 220 nanometres, where the peptide backbone absorbs, and the number reported is the area of the main peak as a proportion of the total area of all peaks.1 That definition contains its own limitations, and the useful ones are these.

Anything that does not absorb at that wavelength is invisible to the measurement. Counterion, water and inorganic salts do not appear in the chromatogram and therefore do not reduce the purity figure, which is precisely why purity and content are separate fields. Impurities that do absorb are counted, but only if the method separates them. A closely eluting related substance can sit inside the main peak as a shoulder and be counted as product, which is the impurity class most likely to hide in a molecule carrying a fatty acid side chain, where incomplete or mispositioned acylation produces something chemically very close to the target. The chromatogram itself is the evidence of whether that happened, so the trace matters more than the number, and the column, gradient, mobile phase and detection wavelength should all be stated.

Two numbers on the same certificate can also mean different things across batches. Bachem is unusually direct about this: a peptide ordered at 80 per cent purity can be delivered anywhere between 80 and 100 per cent, so quantitative results can fluctuate between batches for no reason other than batch quality, and lower purity batches carry other peptidic species that may themselves be biologically active, though not necessarily in the same way as the target, and may interfere with the assay.1

What purity grade is appropriate

GradeApplications it is offered for1
Above 95 per centNMR and crystallography work, and peptides used as a reference in quantitative enzyme substrate, receptor ligand, blocking and competition studies
90 to 95 per centQuantitative enzyme substrate, receptor ligand, blocking, competition and immunoassay work, and in vitro studies
Above 80 per centQualitative work such as western blotting, qualitative enzyme substrate studies and phosphorylation studies
Above 65 per cent, immunogradeProduction of polyclonal antibodies and antibody titre determination

Grades and indications as published by Bachem. The cost of reaching very high purity does not scale linearly, which is why a supplier quoting the same price for every grade is describing a price list rather than a purification strategy.1

In plain English

Purity is a percentage of the peak area on a graph, not a percentage of the powder. Things that do not show up on that graph, like salt and water, cannot lower the number no matter how much of them there is. And an impurity that comes off the column at almost the same moment as the product gets counted as product. That is why the picture of the trace is worth more than the percentage printed beside it.

Content: how much peptide is actually there

Net peptide content is the percentage of the powder that is peptide, as opposed to counterion and moisture, and it is not the same measurement as purity because it counts peptidic contaminants inside the peptide fraction.1 It is typically 60 to 80 per cent of the gross weight and is measured by quantitative amino acid analysis or by elemental analysis of nitrogen.1, 2

Schematic showing a vial labelled 10 mg divided into 7.72 mg target peptide, 0.08 mg peptidic impurities, 1.60 mg counterion and 0.60 mg water, with net peptide content measured against the whole powder and purity measured only against the peptide fraction
The same vial, measured two ways. Purity and net peptide content use different denominators, which is why a batch can be 99 per cent pure and still be less than four fifths peptide.

Two structural features of a sequence make a low figure predictable rather than suspicious. Peptides carrying a large proportion of basic residues bind more counterion, and hydrophilic peptides absorb more atmospheric moisture, so both can show a low net peptide content while being extremely pure.1 Where a measured figure is absent, a theoretical value can be estimated by dividing the molecular weight by the molecular weight plus the number of trifluoroacetate counterions needed to neutralise the molecule multiplied by 114. A peptide of molecular weight 1,000 with a free N terminus and one arginine gives 1,000 divided by 1,228, or 81 per cent.3 That calculation assumes counterion is the only non peptidic component present, so it is a ceiling rather than a measurement.

Three further fields belong in this part of a certificate, and each is measured differently: water content by Karl Fischer titration, residual solvents by gas chromatography, and residual trifluoroacetate or acetate by ion chromatography.1 Bachem’s own conclusion is the one to take away, because it is about assay design rather than paperwork: both the net peptide content and the purity have to be taken into account when preparing solutions of biologically active peptides for assays.1 How that correction is applied to a working concentration is covered in our guide to reconstituting lyophilised peptides.

In plain English

Purity is the share of the peptide that is the right peptide. Net peptide content is the share of the powder that is peptide at all. You need both. A vial can be 99 per cent pure and still be a fifth salt and water, and if you calculate your concentration from the label mass instead of the peptide mass, every number in the study inherits that error.

What else is in the vial

Counterion

Trifluoroacetate is the usual counterion because trifluoroacetic acid is used during synthesis and purification, and it cannot be removed completely, since it is bound as a salt to the free N terminus and to basic side chains. A more biocompatible salt form can be ordered, at the cost of an additional ion exchange step.1, 4 This is not a bookkeeping detail. Cornish and colleagues at the University of Auckland showed that trifluoroacetate on its own, at ten to one hundred nanomolar, reduced cell numbers and thymidine incorporation in osteoblast cultures, and that the trifluoroacetate salts of amylin and calcitonin consistently produced less proliferation than the hydrochloride salts of the same peptides, which meant a real effect was missed or an antiproliferative effect was wrongly attributed to the peptide.5 A certificate that names the salt form allows that to be reasoned about. One that does not, does not.

Endotoxin

Bacterial endotoxin matters wherever the readout is immune, inflammatory or otherwise sensitive to it. Schwarz and colleagues at the University of Salzburg measured endotoxin in commercially available recombinant proteins, found levels broadly in line with the suppliers’ data sheets but some higher, and then showed that lipopolysaccharide at concentrations equivalent to that residual contamination was enough to activate a nuclear factor kappa B reporter system and, more tellingly, primary human CD1c positive dendritic cells. Concentrations as low as 0.02 nanograms per millilitre significantly stimulated cytokine production.6 Their recommendation was that preparations be screened rather than assumed clean.

An honest qualification belongs here. That work concerned recombinant proteins expressed in Escherichia coli, which is a direct source of endotoxin that chemical peptide synthesis does not have. Endotoxin can still enter a synthetic product through water, glassware, chromatography media and handling, which is a documented route of contamination in purified preparations generally.7 The practical position is that an endotoxin figure is essential for cell culture and immunological work and largely irrelevant for a binding assay in buffer, and a certificate that omits it is only a problem if your application is in the first group.

Residual solvents and scavengers

Purified and lyophilised peptides generally carry only trace amounts of cytotoxic non peptidic contaminants such as residual solvents and scavengers left over from synthesis. Unpurified peptides are a different matter, and Bachem’s guidance is that they should not be used for biological assays for exactly this reason.1

In plain English

Three things ride along with the peptide and each can change a result on its own. The salt it was purified with has been shown to slow cell growth by itself. Bacterial endotoxin will light up any immune readout at quantities far too small to see. Leftover synthesis chemicals matter most in material that was never properly purified. None of these show up in a purity percentage, so they need their own lines on the page.

Traceability and who did the testing

Everything above assumes the document describes the vial in front of you. Four fields establish that, and their absence is more informative than any result on the page: a batch or lot number that matches the number printed on the vial, the date the testing was performed, the name of the laboratory that performed it, and the methods used. A certificate that cannot be tied to a specific batch is decorative. A document headed “typical” or “representative” is a specification sheet, not a test result.

Then there is the question of who tested it. A supplier issued certificate is a supplier’s own claim about its own product, which is not worthless but is not independent. A third party report is stronger, though only in proportion to what the laboratory is actually accredited to do. In Australia, laboratory competence is accredited by NATA against ISO/IEC 17025, the international standard for the competence of testing and calibration laboratories, and the important structural point is that accreditation is granted for a defined scope of methods rather than to a laboratory in general.8 So the useful question is not whether a laboratory is accredited. It is whether the method on the report sits inside the scope it is accredited for, and whether the report names that laboratory at all.

What testing of the open market has found

The gap between what labels claim and what vials contain has been measured. In 2024 Ashraf and colleagues published a study in the Journal of Medical Internet Research combining online market surveillance with test purchases and laboratory analysis of semaglutide products bought from illegal online pharmacies. Across the purchased samples, visual inspection of packaging failed between 59 and 63 per cent of the assessed criteria. Measured semaglutide purity ranged from 7.7 to 14.37 per cent against the 99 per cent claimed on the labels. Endotoxin was detected in every sample, between 2.16 and 8.95 endotoxin units per milligram, although no viable microorganisms were found. The measured content of semaglutide per sample exceeded the labelled amount by roughly 29 to 39 per cent, which tells you that these two findings are not contradictory: the vials held more of the compound than stated while being mostly something else.11

That study looked at the illegal medicines market rather than the research supply chain, and the distinction is real. What does not differ is the paperwork, since a certificate is trivial to produce and testing laboratories have reported certificates carrying copied letterheads. Closer to home, seven people in Victoria were hospitalised with acute liver injury during 2026 after using unapproved products labelled as retatrutide, with contamination or mislabelling the leading hypothesis while testing continued.12, 13 Liver toxicity of that kind is not a feature of the pharmaceutical compound in trials, which is covered with the trial data in our article on retatrutide. The batch level analytical question and the safety question turned out to be the same question.

In plain English

When researchers actually bought products online and tested them, the labels were wrong by an enormous margin, and every sample carried bacterial endotoxin. A certificate is a PDF, and a PDF can say anything. What makes it evidence is the batch number matching the vial, a named laboratory, a date, the methods, and the raw traces rather than a table of round numbers.

The checklist

FieldWhat it provesTreat as a warning sign
Mass spectrometry identityThe material weighs what the named molecule should weighAbsent entirely, or a number quoted with no spectrum
HPLC purityThe share of the peptide present that is the intended peptideA percentage with no chromatogram, no column, no gradient, no wavelength
Net peptide contentThe share of the powder that is peptide rather than salt and waterMissing, or silently equated with purity
Water contentResidual moisture, by Karl Fischer titrationMissing on a hygroscopic sequence
Counterion and salt formWhich salt the batch is, and how much of it is presentUnstated, particularly for cell based work
Residual solventsSynthesis and purification solvents remaining, by gas chromatographyMissing on material described as unpurified or crude
EndotoxinBacterial endotoxin load, where the application is immune or inflammatoryMissing when the intended use is cell culture
Batch or lot numberThat the document describes this vialNo number, or a number that does not match the label
Test date and laboratoryWhen the result was generated and by whomUndated, unattributed, or headed “typical”
Accreditation scopeThat the laboratory is assessed as competent for that methodAn accreditation logo with no scope and no method named

Our own position

The checklist above applies to us on the same terms as to anyone else. Where Global Bioanalytical Laboratories provides a certificate with a batch, it is a supplier issued document rather than an independent one, and it should be weighed accordingly. Our quality assurance page is where we set out our testing and documentation. If a field on the checklist is not covered there, the safe assumption is that we do not currently report it, and if you need one that is missing, ask us and you will get a direct answer rather than a marketing one.

Research peptides supplied in Australia are not registered therapeutic goods, have not been assessed by the TGA for quality, safety or efficacy, and several of the compounds discussed on this site are Schedule 4 prescription only medicines, as set out with sources in our article on retatrutide. Through 2026 the TGA has published its compliance position on unapproved peptide products in some detail.9, 10 A certificate of analysis does not change any of that. It answers a narrower question, which is what a laboratory can know about the material it is working with, and that question is worth answering properly.

Common questions

What is a certificate of analysis?

A lot specific summary of the tests run on one batch, issued by whoever ran them. For compounds with no pharmacopoeial monograph the specification is chosen by the issuer rather than set by a regulator, so the document proves what it reports and nothing further.1

Is HPLC purity enough on its own?

No. Purity is the main peak area as a share of total peak area, which describes how much of the peptide present is the intended peptide.1 It cannot confirm what the molecule is, and it cannot see anything that does not absorb ultraviolet light, including salt and water.

Why does net peptide content matter if purity is high?

Because they use different denominators. Net peptide content is commonly 60 to 80 per cent of gross weight, so a 99 per cent pure vial can still be roughly a fifth counterion and water.1, 2 Concentrations calculated from the label mass inherit that gap.

Is a third party certificate always better?

Only in proportion to what the laboratory is accredited for. In Australia, NATA accredits laboratories against ISO/IEC 17025 for a defined scope of methods rather than in general, so the question is whether the reported method falls inside that scope.8

How wrong can a label be?

In a 2024 study of semaglutide products test purchased from illegal online pharmacies, measured purity ranged from 7.7 to 14.37 per cent against 99 per cent claimed, and endotoxin was present in every sample.11 That is the illegal medicines market rather than the research supply chain, but the certificates accompanying such products look much the same.

Disclaimer

Research use only

This article is provided by Global Bioanalytical Laboratories for educational and research reference purposes only. It describes analytical documentation for compounds handled in vitro. It does not constitute medical, legal or regulatory advice, it does not recommend or endorse the use of any compound in humans, and it contains no administration instructions of any kind. Research grade compounds referred to on this website are supplied strictly for laboratory research use and are not for human or veterinary use, diagnosis or treatment. Always consult a registered medical practitioner for health advice.

About this article

Written and reviewed by the Global Bioanalytical Laboratories research team. We compile laboratory references from primary sources: peer reviewed publications, manufacturer analytical guidance, accreditation bodies and Australian regulatory notices. Every factual claim on this page is linked to its source in the reference list below. We supply research peptides, which gives us an interest in this topic, so the standard we describe here is the one published by manufacturers and accreditation bodies rather than one written to flatter our own paperwork.

Spotted an error or a source we have missed? Email support@globalbioanalytical.com.au and we will correct it.

Certificates

Certificates of analysis for GBL products

Certificates of Analysis

References

  1. Bachem. Quality control of amino acids and peptides: a guide. https://www.bachem.com/knowledge-center/quality-control-of-amino-acids-peptides-a-guide/
  2. Biosynth. Analytical methods and quality control for peptide products: net peptide content, amino acid analysis, Karl Fischer titration. https://www.biosynth.com/peptides/peptide-manufacturing/analytics
  3. AAPPTec. Peptide quality: frequently asked questions, theoretical net peptide content. https://www.peptide.com/faqs/peptide-quality/
  4. AnaSpec. Frequently asked questions: peptides, counterions, gross and net peptide weight, salt exchange. https://www.anaspec.com/en/faqs/cat7_peptides
  5. Cornish J, Callon KE, Lin CQX, Xiao CL, Mulvey TB, Cooper GJS, Reid IR. Trifluoroacetate, a contaminant in purified proteins, inhibits proliferation of osteoblasts and chondrocytes. American Journal of Physiology: Endocrinology and Metabolism. 1999;277(5):E779-E783. https://doi.org/10.1152/ajpendo.1999.277.5.E779
  6. Schwarz H, Schmittner M, Duschl A, Horejs-Hoeck J. Residual endotoxin contaminations in recombinant proteins are sufficient to activate human CD1c positive dendritic cells. PLOS ONE. 2014;9(12):e113840. https://doi.org/10.1371/journal.pone.0113840
  7. The dangerous liaisons in innate immunity involving recombinant proteins and endotoxins: examples from the literature and the Leptospira field. Journal of Biological Chemistry. https://www.sciencedirect.com/science/article/pii/S0021925823025346
  8. NATA. Testing and calibration laboratory accreditation to ISO/IEC 17025. https://nata.com.au/accreditation/laboratory-accreditation-iso-iec-17025/
  9. Therapeutic Goods Administration. Understanding your responsibilities when importing, compounding and supplying unapproved peptide products. Safety alert, 2026. https://www.tga.gov.au/safety/safety-monitoring-and-information/safety-alerts/understanding-your-responsibilities-when-importing-compounding-and-supplying-unapproved-peptide-products
  10. Therapeutic Goods Administration. TGA strengthens compliance focus on unapproved peptide products as part of evolving risk response. Media release, 2026. https://www.tga.gov.au/news/media-releases/tga-strengthens-compliance-focus-unapproved-peptide-products-part-evolving-risk-response
  11. Ashraf AR, Mackey TK, Vida RG, Kulcsár G, Schmidt J, Balázs O, Domián BM, Li J, Csákó I, Fittler A. Multifactor quality and safety analysis of semaglutide products sold by online sellers without a prescription. Journal of Medical Internet Research. 2024;26:e65440. https://doi.org/10.2196/65440
  12. Victorian Department of Health. Toxicity linked to unapproved peptide product labelled Retatrutide. Health alert, 19 June 2026. https://www.health.vic.gov.au/health-alerts/toxicity-linked-to-unapproved-peptide-retatrutide
  13. ABC News. Doctors fear possible contaminated counterfeit peptide batch after seventh case of acute liver damage. 24 August 2026. https://www.abc.net.au/news/2026-08-24/contaminated-peptide-tests-liver-damage-hospitalisations/107070478

More research articles